Near Infrared LEDs-Based Non-Invasive Blood Sugar Testing for Detecting Blood Sugar Levels on Diabetic Care

Badriah, Siti and Bahtiar, Yanyan and Andang, Asep (2022) Near Infrared LEDs-Based Non-Invasive Blood Sugar Testing for Detecting Blood Sugar Levels on Diabetic Care. Journal of Biomimetics, Biomaterials and Biomedical Engineering, 55. pp. 183-191. ISSN 2296-9845

WarningThere is a more recent version of this item available.
[img] Text (Artikel)
Artikel Publish JBBE.pdf

Download (1MB)

Abstract

Abstract. Diabetes Mellitus (DM), along with its rapid development and various complications that have caused it, has become one of the deadliest diseases in the world. Early detection efforts to raise blood sugar levels can help to avoid various complications. Measuring devices are needed to find out blood sugar levels detect how much sugar is in the blood. The blood sugar measuring device is invasive by taking blood from capillaries tested both in the lab and using portable testing instruments. The use of this tool results in discomfort, pain, and trauma for the patient. The purpose of this study is to determine the degree of sensitivity of the NIR LED (Near Infrared-Light Emitting Diodes) sensor on the thumb to the little finger to the reading of light reflections coming out of body tissues. Currently, the index finger is often used as a medium to find out how much blood sugar is in non�invasive blood sugar measurements. The other four fingers' sensitivity is unknown at this time. Since the index finger used is located in the middle, it can make difficulty to conduct activities at times, information on the sensitivity level of the other fingers is required. This paper discusses the sensitivity of placing the NIR LED sensor on the five fingers to determine the most sensitive finger with the best response. Based on the testing results of 15 samples, although the index finger receives the most significant stress, the correlation and linear regression tests show that the thumb has the closest relationship with the R2 = 0.6841. With this research, a test instrument with higher sensitivity for Diabetes can be developed by placing the sensor in a comfortable area. The implication is that the results of this study can be recommended to use the thumb as an alternative to the placement of the NIR LED sensor to measure blood sugar levels non-invasively in DM patients

Item Type: Article
Subjects: R Medicine > RT Nursing
Divisions: Jurusan Keperawatan > NERS
Depositing User: Siti Badriah
Date Deposited: 22 Apr 2022 06:08
Last Modified: 22 Apr 2022 06:08
URI: http://repo.poltekkestasikmalaya.ac.id/id/eprint/324

Available Versions of this Item

Actions (login required)

View Item View Item